Lightning Protection & Grounding · SPD Status

Three-Stage SPD and Backup Protection Monitoring for Distribution Cabinets Solutions

Three-stage SPD and backup protection monitoring should establish points separately for the main distribution, sub-distribution and end equipment, and select FS and FSS according to existing or new circuits, aggregating to the platform via FG. The page focuses not on comparing individual SPDs, but on verifying whether protection states at each stage are correlatable, traceable and able to support tiered maintenance.

OVERVIEW

Three-stage SPD and backup protection monitoring should establish points separately for the main distribution, sub-distribution and end equipment, and select FS and FSS according to existing or new circuits, aggregating to the platform via FG. The page focuses not on comparing individual SPDs, but on verifying whether protection states at each stage are correlatable, traceable and able to support tiered maintenance.

This solution addresses the scattered lightning-protection states of main, distribution and end cabinets by establishing a tiered inventory and aggregation chain. When FSS is selected, protection parameters shall be verified circuit by circuit; when FS is selected, only the state interfaces the model can provide shall be used.

Lightning Protection & GroundingSPD Status
Three-Stage SPD and Backup Protection Monitoring for Distribution Cabinets Solutions
BEFORE / AFTER

Before retrofit → With the solution

Before retrofit

  • The SPD states of the main, distribution and end cabinets are scattered among themselves, and a single-point alarm cannot indicate which stage of the protection chain has changed.
  • The definitions of backup protection, SPD body state and lightning events are inconsistent, easily leading to repeated troubleshooting during maintenance.

With the solution

  • Converts the inspection target of tiered lightning protection from a device list into a localizable protection chain.
  • Narrows the scope for judging main, distribution or end circuits after an anomaly appears.
  • Provides a unified state recording method for new and existing circuits.
EFFECT ANALYSIS

How to evaluate the effect

01

Measurable signal

Configure FS state acquisition or FSS integrated smart SPD at the tiers of main distribution, sub-distribution and end circuits, retaining tiered points.

02

Data source

FS SPD Monitoring Module · FG Smart Gateway (Zigbee, RS485 & Ethernet)

03

Review method

The SPD points of the main, distribution and end cabinets can be uniquely corresponded and reflect the tier.

04

Acceptance boundary

The specific parameters, coordination distances and protection selectivity of the three-stage SPD must be confirmed by the design documents.

STANDARDS

Applicable standards

Standards and protocols are listed for project applicability review; the final clause set and edition follow the project location, industry and contract.

GB 50057 Design Code for Lightning Protection of Buildings (applicable clauses and version to be confirmed by the project location and design documents)GB/T 18802 series of standards for low-voltage surge protective devices (test category, model and version to be confirmed by the project)
ACCEPTANCE

Acceptance and boundaries

  • The SPD points of the main, distribution and end cabinets can be uniquely corresponded and reflect the tier.
  • Backup protection state and SPD state are recorded separately and are not merged into one item in the data model.
  • An alarm at any tier can be traced to occurrence time, device location and subsequent handling.
PAIN POINTS

Industry Pain Points

01

The SPD states of the main, di…

The SPD states of the main, distribution and end cabinets are scattered among themselves, and a single-point alarm cannot indicate which stage of the protection chain has changed.

02

The definitions of backup prot…

The definitions of backup protection, SPD body state and lightning events are inconsistent, easily leading to repeated troubleshooting during maintenance.

ARCHITECTURE

Solution Architecture

Layered architecture, a complete data loop from sensing to operation.

Three-Stage SPD and Backup Protection Monitoring for Distribution Cabinets system topologyFour-layer data flow from perception and edge control to the platform and application layers for Three-Stage SPD and Backup Protection Monitoring for Distribution Cabinets.01Perception layer
Configure FS state acquisition or FSS integrated smart SPD at the tiers of main distribution…
02Edge / control layer
FG aggregates devices by distribution area and establishes naming rules by cabinet number, t…
03Platform layer
FEXLINK displays alarms, historical events and handling status by main, distribution and end…
04Application layer
O&M personnel first determine the tier of the anomaly, then enter the corresponding distribu…
Perception layer
Configure FS state acquisition or FSS integrated smart SPD at the tiers of main distribution, sub-distribution and end circuits, retaining tiered points.
Edge / control layer
FG aggregates devices by distribution area and establishes naming rules by cabinet number, tier and circuit.
Platform layer
FEXLINK displays alarms, historical events and handling status by main, distribution and end cabinets.
Application layer
O&M personnel first determine the tier of the anomaly, then enter the corresponding distribution area for verification, avoiding repeated cross-tier checks.
CORE CAPABILITIES

Core Capabilities

Product 1

FS SPD Monitoring Module

Used to collect telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are to be confirmed by the FS model.

Product 2

FG Smart Gateway (Zigbee, RS485 & Ethernet)

Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.

Product 3

FEXLINK IoT Platform

Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.

Product 4

FSS Smart Surge Protective Device (Flagship)

As an integrated smart SPD combining protection and condition monitoring, it is selected by number of poles, protection parameters and circuit conditions.

DATA LOOP

Data Loop

The complete data value chain: sense -> data -> AI -> warning -> control -> operation.

01Site sensing
02Edge aggregation
03Platform analysis
04Alarm handling
05O&M closure
PRODUCT PORTFOLIO

Product Portfolio

Lightning Protection & Grounding

FS SPD Monitoring Module

FS SPD Monitoring Module

Used to collect telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are to be confirmed by the FS model.

Lightning Protection & GroundingSPD Status
SPD Status

FG Smart Gateway (Zigbee, RS485 & Ethernet)

FG Smart Gateway (Zigbee, RS485 & Ethernet)

Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.

Lightning Protection & GroundingSPD Status
Lightning Protection & Grounding

FEXLINK IoT Platform

FEXLINK IoT Platform

Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.

Lightning Protection & GroundingSPD Status
SPD Status

FSS Smart Surge Protective Device (Flagship)

FSS Smart Surge Protective Device (Flagship)

As an integrated smart SPD combining protection and condition monitoring, it is selected by number of poles, protection parameters and circuit conditions.

Lightning Protection & GroundingSPD Status
CUSTOMER VALUE

Customer Value

Quantified, verifiable customer value.

Converts the inspection ta…

Converts the inspection target of tiered lightning protection from a device list into a localizable protection chain.

Lightning Protection & GroundingSPD Status

Narrows the scope for judg…

Narrows the scope for judging main, distribution or end circuits after an anomaly appears.

Lightning Protection & GroundingSPD Status

Provides a unified state r…

Provides a unified state recording method for new and existing circuits.

Lightning Protection & GroundingSPD Status
RELATED SOLUTIONS

Related Solutions

Online Condition Monitoring of Incoming SPDs in Power Distribution Rooms

This solution addresses the digitalization of lightning-protection status for incoming cabinets in existing power distribution rooms, focusing on the problem that SPD failures and event records rely on manual discovery. The solution starts from available dry contacts, telemetry signals or count information, and avoids describing basic condition monitoring as a full service-life diagnosis.

Lightning Protection & GroundingSPD Status

Integrated Smart SPD Solution for New Circuits

This solution moves protection, monitoring and event recording forward to new or wholly replaced circuits. The core of selection is protection parameters and on-site installation conditions; platform access cannot replace design verification.

Lightning Protection & GroundingSPD Status

End-Stage SPD and Precision-Equipment Lightning Protection Monitoring for Equipment Rooms

This solution addresses surge risk for end precision equipment in equipment rooms, establishing compact monitoring with ESM-21001 or an applicable ESM model. The page focuses on end-stage SPD, device compatibility and low-disturbance implementation, and does not extend condition monitoring into an equipment-reliability commitment.

Lightning Protection & GroundingSPD StatusLightning Protection Monitoring

Smart Monitoring Retrofit for Plug-in SPD Bases

This solution integrates the states and events of compatible modules into unified monitoring without wholly replacing qualified plug-in SPDs. The core is not replacing protection devices, but completing the engineering closed loop of interfaces, power supply, communication and alarm records.

Lightning Protection & GroundingSPD Status

Basic SPD Monitoring for Compact Power Distribution Cabinets

The scheme centers on a narrow-body basic monitoring terminal and a field gateway, prioritizing solving device installability, state uploadability and alarm recordability, avoiding increased in-cabinet retrofit difficulty from pursuing all parameters.

Lightning Protection & GroundingSPD Status

Dry-Contact State Aggregation for Existing SPDs

This is a low-modification state-digitization scheme, focusing on integrating existing telemetry into the unified platform rather than adding new sensing capability to all existing SPDs.

Lightning Protection & GroundingSPD StatusDigital Input Acquisition
FAQ

FAQ

No. FSS or FS should be selected separately according to new or existing status, protection parameters, interfaces and in-cabinet space, and the platform manages them uniformly with tiered points.
Not directly. The two monitor different objects and must be defined separately in the point list and device interfaces.
Technically it can be aggregated, but losing tiered information is not recommended; at minimum, the cabinet tier and device tier should be retained for localization.
FS: collects telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are confirmed by the FS model; FG: aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform; FEXLINK: provides device management, alarm, historical data, permission and O&M record capabilities, with the deployment method confirmed by the project; FSS: as an integrated smart SPD combining protection and condition monitoring, selected by number of poles, protection parameters and circuit conditions.
For new or fully replaced circuits, prioritize evaluating FSS, and select by In, Imax, Up, number of poles and short-circuit conditions; for existing circuits, select FS after confirming the connectable telemetry signals and auxiliary contacts; when backup protection signals are absent, SPD state must not be directly equated with backup protection having operated.
The SPD points of the main, distribution and end cabinets can be uniquely corresponded and reflect the tier; backup protection state and SPD state are recorded separately and are not merged into one item in the data model; an alarm at any tier can be traced to occurrence time, device location and subsequent handling.

Start Three-Stage SPD and Backup Protection Monitoring for Distribution Cabinets Journey

Contact us for detailed solutions, quotes and technical support.