Direct Lightning Current Peak and Event Recording Solutions
Direct lightning current event recording should, under the condition of clarified down-conductor path, conductor size and installation orientation, adopt an applicable FL lightning-current recording device and aggregate via FG. The page may describe event time, path and recording purpose, but peak range, waveform capability, protection rating and installation method must be confirmed by the specific model and datasheet.
Direct lightning current event recording should, under the condition of clarified down-conductor path, conductor size and installation orientation, adopt an applicable FL lightning-current recording device and aggregate via FG. The page may describe event time, path and recording purpose, but peak range, waveform capability, protection rating and installation method must be confirmed by the specific model and datasheet.
This solution reduces the problem of lacking event evidence after a lightning strike. The starting point of data value is correctly selecting the monitored conductor and installation location, rather than inferring the lightning path from alarms alone after the fact.
Before retrofit → With the solution
Before retrofit
- Lightning strike occurrence time, path and count lack continuous records, making after-the-fact reconstruction difficult.
- Down-conductor size, coil orientation, outdoor environment and device protection conditions are inconsistent, so the installation method cannot be universal.
With the solution
- Provides a time basis for facility inspection after a lightning strike.
- Helps O&M distinguish lightning events from ordinary equipment faults.
- Forms traceable lightning-protection operation records.
How to evaluate the effect
Measurable signal
Install an applicable FL recording device on a confirmed down conductor or lightning-current path.
Data source
FL Lightning Current / Transient Current Monitor · FG Smart Gateway (Zigbee, RS485 & Ethernet)
Review method
The monitoring point establishes a unique correspondence with the protected object, down conductor or facility.
Acceptance boundary
Lightning-current recording alone cannot prove that the protected equipment is definitely damaged or undamaged.
Applicable standards
Standards and protocols are listed for project applicability review; the final clause set and edition follow the project location, industry and contract.
Acceptance and boundaries
- The monitoring point establishes a unique correspondence with the protected object, down conductor or facility.
- Event records have device, time and state information, and can distinguish communication anomalies.
- The installation method and protection treatment are inspected on site without changing the function of the original lightning-protection down conductor.
Industry Pain Points
Lightning strike occurrence ti…
Lightning strike occurrence time, path and count lack continuous records, making after-the-fact reconstruction difficult.
Down-conductor size, coil orie…
Down-conductor size, coil orientation, outdoor environment and device protection conditions are inconsistent, so the installation method cannot be universal.
Solution Architecture
Layered architecture, a complete data loop from sensing to operation.
Core Capabilities
FL Lightning Current / Transient Current Monitor
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
FG Smart Gateway (Zigbee, RS485 & Ethernet)
Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.
FEXLINK IoT Platform
Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.
Data Loop
The complete data value chain: sense -> data -> AI -> warning -> control -> operation.
Product Portfolio
FL Lightning Current / Transient Current Monitor
FL Lightning Current / Transient Current Monitor
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
FG Smart Gateway (Zigbee, RS485 & Ethernet)
FG Smart Gateway (Zigbee, RS485 & Ethernet)
Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.
FEXLINK IoT Platform
FEXLINK IoT Platform
Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.
Customer Value
Quantified, verifiable customer value.
Provides a time basis for …
Provides a time basis for facility inspection after a lightning strike.
Helps O&M distinguish ligh…
Helps O&M distinguish lightning events from ordinary equipment faults.
Forms traceable lightning-…
Forms traceable lightning-protection operation records.
Related Solutions
Induced Lightning and Transient Current Monitoring
This solution is for observing small-current transient events with a clarified range. Before implementation, different phenomena such as direct lightning, induced lightning and equipment-switching overvoltage must be distinguished, to avoid interpreting data from one channel as a complete source determination.
Lightning Current Monitoring for Wind Turbine Blade Down Conductors
This solution forms continuous records of wind-turbine lightning events, providing a time basis for blade, SPD and grounding verification. The product combination and installation location must comply with the turbine model structure and on-site maintenance process.
Online Grounding Resistance Monitoring for Substations and Distribution Stations
This solution reduces blind spots in manual grounding testing and establishes traceable monitoring records. FR-01311 applies to three-electrode-method scenarios with auxiliary-electrode conditions; when such conditions are unavailable, re-evaluate the FRP loop method or other monitoring methods.
Grounding Continuity Monitoring for Distribution Cabinets and Equipment Cabinets
This solution focuses on the connection state between the cabinet body, door panels, grounding busbars and equipment enclosures. During implementation, first establish a grounding path diagram and measurement-point inventory, then select the loop method or other applicable products, to avoid generating invalid alarms at unreliable contacts.