Ground Resistance · Online Monitoring · Three-Pole Method

Ground-Resistance Online Monitoring System Solutions

Three-pole/loop-method dual-mode online monitoring replaces manual inspection and prevents personal and equipment accidents caused by grounding faults.

OVERVIEW

Three-pole/loop-method dual-mode online monitoring replaces manual inspection and prevents personal and equipment accidents caused by grounding faults.

Based on FR-series three-pole monitors and FRP-series loop-method monitors, it delivers 7x24 continuous online ground-resistance monitoring. The FR series (fall-of-potential method) measures 0.01ohm to 2000ohm for precise measurement of new grounding systems; the FRP series uses contactless loop-method measurement without auxiliary electrodes for rapid surveys of existing grounding systems, with an explosion-proof Ex ia IIC T4 option for petrochemical scenarios.

Ground ResistanceOnline MonitoringThree-Pole MethodLoop-Method
Ground-Resistance Online Monitoring System Solutions
PAIN POINTS

Industry Pain Points

01
📏

Long Manual Measurement Cycles, Low Precision

Conventional ground-resistance measurement relies on periodic manual testing; cycles are long, efficiency is low, and data cannot be obtained promptly in bad weather.

02
⚠️

Delayed Grounding-Fault Detection

Grounding status changes after lightning strikes or faults are not captured in time; delayed detection can lead to personal and equipment accidents.

03
🔥

High Risk of Manual Measurement in Hazardous Areas

Manual measurement in explosion-hazard zones such as petrochemical tank farms carries safety risks; ordinary test equipment cannot enter, leaving grounding unmonitored.

04
🗂️

Difficult Scattered Multi-Point Management

Substations, telecom base stations and wind farms have widely distributed measurement points without unified aggregation or centralized management.

ARCHITECTURE

Solution Architecture

Layered architecture, a complete data loop from sensing to operation.

Monitoring Layer
FR Three-Pole MonitorFRP Loop-Method MonitorIndoor Rail/Screw/Outdoor TypesExplosion-Proof Ex ia IIC T40.01-2000ohm Measurement
Communication Layer
RS-485 Wired NetworkingLoRa Wireless NetworkingESX Intelligent Edge Computing Gateway Aggregation4G Cloud UplinkMulti-Point Synchronous Acquisition
Platform Layer
FEXLINK CloudGround-Resistance DashboardTrend AnalysisTiered AlarmingLightning-Event Correlation
Application Layer
PC + Mobile Remote ViewingGrounding-System Assessment ReportOn-Demand InspectionAudit Traceability
CORE CAPABILITIES

Core Capabilities

📐
Capability 1

Three-Pole/Loop-Method Dual Mode

FR series supports precise three-pole (fall-of-potential) measurement; FRP series supports fast loop-method surveys without auxiliary electrodes, adapting to different scenarios.

🎯
Capability 2

High Precision, Wide Range

0.01ohm-2000ohm measurement range with high precision and stability, meeting grounding standards across industries.

🌡️
Capability 3

Multi-Point Synchronous Monitoring

Multiple monitors in one network acquire synchronously with centralized comparison and analysis, covering large distributed grounding systems.

📈
Capability 4

Smart Trend Analysis

Automatic analysis of ground-resistance trends with seasonal/weather changes for scientific status assessment and tiered over-limit alarming.

🔔
Capability 5

Tiered Over-Limit Alarming

Configurable multi-level thresholds; automatic alarm push to responsible personnel via SMS/APP/email on exceedance.

🌩️
Capability 6

Lightning-Event Logging

Automatic correlation with lightning-current data, recording strike time and ground-resistance changes to support lightning-protection analysis.

DATA LOOP

Data Loop

The complete data value chain: sense -> data -> AI -> warning -> control -> operation.

01Real-Time Acquisition
02Data Aggregation
03Trend Analysis
04Tiered Alarming
05Assessment Loop
80%O&M Cost Reduction
90%Faster Fault Response
0.01ohmMinimum Measurement Precision
7x24Continuous Online Monitoring
PRODUCT PORTFOLIO

Product Portfolio

📐
Three-Pole Method

FR Ground-Resistance Monitor

FR Series. Ground-Resistance Online Monitoring System Solutions Solution | YESLON var _hmt = _hmt || []; (function () { var hm = document.

Fall-of-potential three-pole measurement over 0.01ohm-2000ohm with high precision and stability for precise measurement of new grounding systems.

Fall-of-Potential0.01-2000ohmHigh Precision
📏
Loop-Method

FRP Loop-Method Ground-Resistance Monitor

FRP Series. Ground-Resistance Online Monitoring System Solutions Solution | YESLON var _hmt = _hmt || []; (function () { var hm = document.

Contactless loop-method measurement without auxiliary electrodes for rapid surveys of existing systems; explosion-proof Ex ia IIC T4 for petrochemical scenarios.

Loop-MethodNo Auxiliary ElectrodesExplosion-Proof
📡
Smart Gateway

FG Smart Lightning-Protection Gateway

ESX Series. Ground-Resistance Online Monitoring System Solutions Solution | YESLON var _hmt = _hmt || []; (function () { var hm = document.

Unified aggregation of FR/FRP data with RS-485/LoRa networking and 4G cloud uplink for centralized multi-point management.

Data AggregationMulti-Mode CommunicationCentralized Management
⚡
Strike Correlation

FL Lightning-Peak Monitor

FL Series. Ground-Resistance Online Monitoring System Solutions Solution | YESLON var _hmt = _hmt || []; (function () { var hm = document.

Records lightning-current peaks and occurrence time, correlating with ground-resistance data for comprehensive lightning-protection assessment.

Peak LoggingEvent CorrelationLightning Analysis
CUSTOMER VALUE

Customer Value

Quantified, verifiable customer value.

📏

Inspection Frequency From Monthly to On-Demand

7x24 continuous online monitoring replaces manual monthly inspection, cutting inspection frequency from monthly to on-demand and O&M costs by 80%.

Online MonitoringOn-Demand Inspection80% Cost Saving
⚠️

90% Faster Grounding-Fault Response

Tiered over-limit alarms push instantly; lightning events correlate automatically, cutting grounding-fault response time by 90% and preventing personal and equipment accidents.

Instant AlarmsEvent CorrelationFaster Response
🔥

Safe Monitoring in Hazardous Areas

Explosion-proof Ex ia IIC T4 intrinsically-safe design meets petrochemical requirements; grounding status in hazardous zones is remotely visible with zero-risk inspection.

Explosion-Proof CertificationIntrinsically SafeRemote Visibility
📊

Traceable Data, Worry-Free Audits

Centralized grounding data storage with automatic assessment reports compliant with GB 50057/GB/T 21431 for worry-free audits.

Data TrailAutomatic ReportsStandard Compliance
FAQ

FAQ

The FR series uses the fall-of-potential three-pole method over 0.01ohm-2000ohm with high precision and stability for precise measurement of new grounding systems; the FRP series uses contactless loop-method measurement without auxiliary electrodes, especially suited to rapid surveys and retrofit projects of existing grounding systems.
The FRP series offers an explosion-proof Ex ia IIC T4 product with intrinsically-safe design meeting petrochemical requirements, deployable safely in hazardous zones with real-time remote visibility of grounding status.
FR/FRP monitors network via RS-485 wired or LoRa wireless, aggregated by ESX intelligent edge computing gateways and uplinked via 4G; the FEXLINK Cloud provides ground-resistance dashboards, trend analysis, tiered alarming and lightning-event correlation records.
The system is widely applied in substations, telecom base stations, petrochemical tank farms, wind farms and building lightning-protection grounding, cutting inspection frequency from monthly to on-demand, O&M costs by 80% and grounding-fault response time by 90%.

Ground-Resistance Online Monitoring System Solutions provides on-site sensing, early warning and data uplink with standard protocols.

Start Ground-Resistance Online Monitoring System Journey

Contact us for detailed solutions, quotes and technical support.