Smart Lightning Protection

FSP Surge-Protection Base

FSP Series

Plug-in smart surge base; standard SPDs insert directly to become smart, with lightning counting, temperature monitoring and remote-signaling alarm.

Plug-inLightning countTemperature monitoringRemote signaling
FSP Surge-Protection Base

Product Overview

The FSP Lightning Protection Monitoring Base is a plug-in smart surge protective device with an appearance basically identical to traditional lightning arresters, and pluggable modules of conventional lightning arresters can be inserted directly into the base. The base integrates a high-precision main control board; no complex configuration is required — plug in the terminals and it becomes smart. The product covers the protection requirements of Class T2 lightning arresters and part of the protection requirements of Class T1 lightning arresters, and is widely applied in power usage scenarios across various fields. It supports RS485 communication for easy integration into third-party monitoring platforms. Integrating "acquisition, measurement, transmission and intelligence" with an all-built-in sensor design, it still retains pluggable modules with local display and requires no external power supply.

Core Capabilities

Pluggable design compatible with conventional modules, with an exquisite and compact appearance. All-in-one "acquisition, measurement, transmission and intelligence" with fully built-in sensors. Built-in lightning sensor with strike counting of 0~9999 and minimum trigger of 0.1kA. Real-time monitoring of the SPD internal trip connection status; if any channel trips and disconnects, a local red light alarm is triggered. Product Features

Data Generated

Plug-inLightning countTemperature monitoringRemote signaling

Product Features

Highly Integrated

The product covers the protection requirements of Class T2 lightning arresters and part of the protection requirements of Class T1 lightning arresters, and is widely applied in power usage scenarios across various fields. Supports RS485 communication for easy integration into third-party monitoring platforms.

Widely Applicable

Temperature monitoring: built-in temperature sensor that continuously tracks temperature changes of the surge module. Lightning strike counting: built-in lightning sensor that captures lightning intrusion data with high precision.

Powerful Functions

Supports linkage control (with matching dedicated gateway), digital tube display and pluggable design; the exquisite and compact appearance allows easy replacement of existing lightning arresters. No external power supply required, supports caching and the standard MODBUS protocol.

Convenient and Compact

Exquisite and compact appearance for easy replacement of existing lightning arresters; pluggable design compatible with conventional modules; plug in the terminals and it becomes smart, with no complex configuration required.

Trip Remote Signaling Alarm

Real-time monitoring of the SPD internal trip connection status; if any channel trips and disconnects, a local red light alarm is triggered immediately to indicate failure risk and prevent accidents caused by lightning protection failure.

Multiple Power Supply Versions Available

Available in AC220V-powered and DC5V-powered versions to suit different power takeoff conditions of distribution cabinets, offering flexible selection and easy deployment. Selection Guide

System Topology

Perception LayerElectrical Parameters · Leakage Detection · Temperature · Arc · Lightning Current · SPD StatusEdge LayerEdge Gateway · Smart Circuit Breaker · Protocol Acquisition · Rule EnginePlatform LayerFEXLINK Cloud · W-Link · Device Access · Data StorageApplication LayerIndustrial AI Analysis · Virtual Power Plant · Energy Monitoring · Carbon Assets · Carbon-Neutral Park

Selection Guide

Model Naming Rules

FSP - 2 1 0 0 0 - R FSP Product Lightning protection monitoring base 2 Power supply 2=AC220V; 1=DC5V 1 Display 1=Digital tube 0 Remote signaling 1=Yes; 0=No 0 Lightning strike counting 1=Yes; 0=No 0 Temperature 1=Yes; 0=No R Communication method R=RS485 Model Power supply Display Remote signaling input Lightning strike counting Temperature monitoring Communication method FSP-21000-R AC220V Digital tube 1 channel None None RS485 Modbus FSP-21100-R AC220V Digital tube 1 channel Yes None RS485 Modbus FSP-11000-R DC5V Digital tube 1 channel None None RS485 Modbus FSP-11100-R DC5V Digital tube 1 channel Yes None RS485 Modbus Technical Parameters

ModelPower Supply / Display / Remote Signaling Input / Lightning Strike Counting / Temperature Monitoring / Communication Method
FSP-21000-RAC220V / Digital tube / 1 channel / None / None / RS485 Modbus
FSP-21100-RAC220V / Digital tube / 1 channel / Yes / None / RS485 Modbus
FSP-11000-RDC5V / Digital tube / 1 channel / None / None / RS485 Modbus
FSP-11100-RDC5V / Digital tube / 1 channel / Yes / None / RS485 Modbus

Technical Parameters

Basic Parameters

Operating voltage AC 220V / DC 5V Product power consumption ≤2W Operating temperature -20℃~60℃ Operating humidity <95% Product weight 155g Dimensions 72*83*50mm (L×W×H) Housing material Thermoplastic UL94V0 Protection rating IP20 Mounting method Standard 35mm DIN rail Display method Digital tube

Operating voltageAC 220V / DC 5V
Product power consumption≤2W
Operating temperature-20℃~60℃
Operating humidity<95%
Product weight155g
Dimensions72*83*50mm (L×W×H)
Housing materialThermoplastic UL94V0
Protection ratingIP20
Mounting methodStandard 35mm DIN rail
Display methodDigital tube

Smart Monitoring Functions

Communication method RS485 Communication protocol Modbus Remote signaling input Monitors SPD status (trip connection status) Lightning strike counting 0~9999, minimum trigger 0.1kA Temperature monitoring Built-in measurement: -30~125℃, ±1℃ Local alarm Red light alarm if any channel trips and disconnects Caching Supported Linkage control Supported (with matching dedicated gateway) Installation Instructions

Communication methodRS485
Communication protocolModbus
Remote signaling inputMonitors SPD status (trip connection status)
Lightning strike counting0~9999, minimum trigger 0.1kA
Temperature monitoringBuilt-in measurement: -30~125℃, ±1℃
Local alarmRed light alarm if any channel trips and disconnects
CachingSupported
Linkage controlSupported (with matching dedicated gateway)

Installation Instructions

a

Installation Dimension Diagram

72mm Length 83mm Width 50mm Height 35mm Standard DIN rail b

Interface Description

Interface definitions Category Number Definition Lightning arrester L1 Phase A L2 Phase B L3 Phase C N Neutral wire PE Ground wire Power supply * External 5VDC (externally powered version) GND 0V RS485 communication A RS485 A terminal B RS485 B terminal Button R Settings and counter reset

CategoryNumber / Definition
Lightning arresterL1 / Phase A
L2Phase B
L3Phase C
NNeutral wire
PEGround wire
Power supply* / External 5VDC (externally powered version)
GND0V
RS485 communicationA / RS485 A terminal
BRS485 B terminal
ButtonR / Settings and counter reset

Key Points

Definition: The FSP Lightning Protection Monitoring Base is FEXLINK's plug-in smart surge protective device base that integrates "acquisition, measurement, transmission and intelligence", used with pluggable SPD modules. Core capabilities: supports hot-swap replacement of SPD modules, built-in leakage current, temperature and lightning strike count monitoring, and works with FSS series modules for full-element status sensing and service life estimation. Applicable scenarios: suitable for distribution cabinets, equipment racks and other scenarios that require frequent maintenance or replacement of SPD modules. Related products: FSS Smart Surge Protective Device, FS Surge Protective Device Monitor, ESX Intelligent Edge Computing Gateway.

FAQ

The FSP Lightning Protection Monitoring Base is FEXLINK's plug-in smart surge protective device base that integrates "acquisition, measurement, transmission and intelligence" in one unit, used with pluggable SPD modules.
It is suitable for distribution cabinets, equipment racks and other scenarios that require frequent maintenance or replacement of SPD modules.
Compared with all-in-one SPDs, the FSP base features a separated design with pluggable modules, making maintenance and replacement more convenient without powering off and disassembling the entire SPD.
Mount on a standard 35mm DIN rail, insert the matching SPD module, and connect via L/N and the A/B RS485 bus.
You can submit your requirements via the contact page on the FEXLINK official website, or call 0755-8653 6148 to book a demo and selection consultation. Our engineers will provide matching solutions and quotes based on your application scenario.

Related Products

RecommendedFS Lightning-Protection Monitor

FS Lightning-Protection Monitor

FS-33211

SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

SPD online monitoringuA-level leakageFour/Five-element / Nine-elementLife trend
View Details →Smart Lightning Protection
FSS Smart Surge Protective Device

FSS Smart Surge Protective Device

FSS Series

Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.

Integrated smart SPDLCD/OLEDBuilt-in communicationStatus monitoring
View Details →Smart Lightning Protection
FL Lightning-Current Monitor

FL Lightning-Current Monitor

FL Series

Peak lightning current 0.1-200kA measurement, GPS/BeiDou timing, IP67 outdoor protection, precise lightning-event attribution.

0.1-200kA peakGPS/BeiDouIP67Event attribution
View Details →Smart Lightning Protection
Related TopicsIndustry keywords related to this page
Lightning Protection
Lightning Early Warning InterfaceLightning Early Warning SelectionLightning Monitoring FeaturesLightning Early Warning ProspectLightning Early Warning StatusLightning Early Warning DefinitionLightning Early Warning AdvantagesLightning Monitoring IntroductionLightning Early Warning HandbookLightning Protection Monitoring CasesLightning Monitoring SignificanceLightning Early Warning SpecificationLightning Early Warning DisadvantagesLightning Protection Monitoring DisadvantagesLightning Monitoring ProtocolLightning Monitoring SpecificationLightning Monitoring DefinitionLightning Monitoring InterfaceLightning Protection Monitoring AdvantagesLightning Protection Monitoring InterfaceLightning Protection Monitoring ProtocolLightning Protection Monitoring DefinitionLightning Protection Monitoring StatusLightning Early Warning ProtocolLightning Protection Monitoring BenefitsLightning Protection Monitoring ProspectLightning Monitoring ConceptLightning Monitoring TutorialLightning Protection Monitoring DownloadLightning Monitoring Handbook
Equipment Health
Equipment Health MonitoringVibration MonitoringTemperature MonitoringInfrared ThermometryMotor Status MonitoringRotating Equipment MonitoringPump Monitoring ConceptPump Monitoring InterfacePump Monitoring ComparisonPump Monitoring SelectionPump Monitoring StatusPump Monitoring AdvantagesPump Monitoring ValuePump Monitoring National StandardPump Monitoring SignificancePump Monitoring SpecificationPump Monitoring MaterialsPump Monitoring CasesPump Monitoring ProspectPump Monitoring TutorialPump Monitoring DisadvantagesPump Monitoring FunctionPump Monitoring BenefitsPump Monitoring FeaturesPump Monitoring StandardPump Monitoring DefinitionPump Monitoring ProtocolPump Monitoring HandbookPump Monitoring DownloadPump Monitoring Difference

Learn MoreFSP Surge-Protection Base Application Scenarios

Contact us for detailed solutions, quotes and technical support.