Smart Lightning Protection

T2 Shield-Link Surge Protective Device

ZL2-V-x/275-4P

Shield-link T2 surge protective device with multi-pole one-piece construction for better inter-phase equipotential bonding; used for first-level shield-link protection at sub-distribution and equipment ends.

100kAShield-link body≤50ns
T2 Shield-Link Surge Protective Device

Product Overview

Shield-link T2 surge protective device with multi-pole one-piece construction for better inter-phase equipotential bonding; used for first-level shield-link protection at sub-distribution and equipment ends.

Core capabilities

Direct Strike Coordination: Forms two-stage discharge together with T1 devices. Nanosecond Response: ≤50ns clamping of overvoltages. Shield-Link Structure: Multi-pole one-piece body, better inter-phase equipotential bonding.

Data Generated

100kAShield-link body≤50ns

Product Features

Direct Strike Coordination

Forms two-stage discharge together with T1 devices

Nanosecond Response

≤50ns clamping of overvoltages

Shield-Link Structure

Multi-pole one-piece body, better inter-phase equipotential bonding

Local Failure Indication

Window colour change for identification

Remote Signalling

Optional dry contact on ZLS2 series

Flexible Configurations

2P/4P with 275V/385V combinations

System Topology

Perception LayerElectrical Parameters · Leakage Detection · Temperature · Arc · Lightning Current · SPD StatusEdge LayerEdge Gateway · Smart Circuit Breaker · Protocol Acquisition · Rule EnginePlatform LayerFEXLINK Cloud · W-Link · Device Access · Data StorageApplication LayerIndustrial AI Analysis · Virtual Power Plant · Energy Monitoring · Carbon Assets · Carbon-Neutral Park

Technical Parameters

Technical Data

Protection class T2 Structure Shield-link one-piece multi-pole Maximum continuous operating voltage Uc 275V / 385V Nominal discharge current In 10 / 20 / 30 / 40kA Maximum discharge current Imax 20 / 40 / 60 / 80 / 100kA Voltage protection level Up 1.5kV / 1.8kV

Protection classT2
StructureShield-link one-piece multi-pole
Maximum continuous operating voltage Uc275V / 385V
Nominal discharge current In10 / 20 / 30 / 40kA
Maximum discharge current Imax20 / 40 / 60 / 80 / 100kA
Voltage protection level Up1.5kV / 1.8kV
Response time≤50ns
Poles2P / 4P
MountingStandard 35mm DIN rail
Remote signallingOptional on ZLS2 series
Protection degreeIP20

Installation Instructions

Standard 35 mm DIN rail mounting; terminals: supply side L1/L2/L3, N, PE, communication and signal terminals as marked on the device.

Key Points

FAQ

The shield-link body builds several poles into one piece, giving better inter-phase equipotential bonding and consistency. Plug-in units use independent modules mounted on a base.
It is designed to T2 class and is normally combined with a T1 device to form two-stage protection. Where it is used alone, lightning risk and surge current must be calculated.
Up is 1.5kV at 275V and 1.8kV at 385V. Response time is ≤50ns for the series, and local failure indication is provided on the device.
Mounting is on a standard 35mm rail, and the ZLS2 series offers an optional dry signalling contact for remote failure reporting.
Certification is CE / CMA / CNAS accredited laboratory. Price is Request a quote, with lead time and configuration agreed per project.

Related Products

RecommendedFS Lightning-Protection Monitor

FS Lightning-Protection Monitor

FS-33211

SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

SPD online monitoringuA-level leakageFour/Five-element / Nine-elementLife trend
View Details →Smart Lightning Protection
FSS Smart Surge Protective Device

FSS Smart Surge Protective Device

FSS Series

Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.

Integrated smart SPDLCD/OLEDBuilt-in communicationStatus monitoring
View Details →Smart Lightning Protection
FL Lightning-Current Monitor

FL Lightning-Current Monitor

FL Series

Peak lightning current 1kA-120kA measurement, GPS/BeiDou timing, IP67 outdoor protection, precise lightning-event attribution.

1kA-120kA peakGPS/BeiDouIP67Event attribution