T2 Surge Arrester (MOV Type)
ZL2-V Series
Class II secondary protection, nominal 20kA / max 40kA discharge, low residual voltage Up 1.5kV, response <=50ns, 2P/4P, 35mm rail mass deployment.

Product Overview
The Type 2 varistor surge protective device complies with Type 2 power surge protection standards. Installed between the power supply system and equipment, it suppresses induced lightning strikes and internal grid overvoltages. With high-quality varistor elements, it delivers large discharge capacity and low residual voltage output, responds rapidly, and effectively reduces the risk of equipment damage. The product supports 2P/4P wiring modes, features a built-in failure indication window, standard 35mm DIN-rail mounting, and a compact structure with a small footprint, ideal for batch deployment in distribution cabinets. Models with "S" remote signal feature built-in dry contacts that can be connected to monitoring systems to report failure status.
Core Capabilities
Type 2 lightning protection with a nominal discharge current of 20kA and maximum of 40kA. Voltage protection level as low as 1.5kV with ≤50ns response time. Multiple 2P/4P specifications compatible with various Uc voltages of 275V/385V. Models with "S" support remote signal monitoring to report failure status. Product Features
Data Generated
Product Features
Type 2 Lightning Protection
Complies with Type 2 power surge protection standards, discharging induced lightning strikes and internal grid overvoltages to effectively reduce the risk of equipment damage.
Large Discharge Capacity
Nominal discharge current of 20kA (max 40kA), capable of withstanding high-energy surges in demanding surge environments.
Low Residual Voltage Output
Voltage protection level as low as 1.5kV with ≤50ns response time, quickly clamping overvoltages to protect downstream equipment.
Multiple Specification Compatibility
Offers 2P, 4P, and multiple Uc voltages (275V/385V, etc.), compatible with AC/DC systems to meet different distribution line requirements.
Remote Signal Monitoring
Models with "S" remote signal feature built-in dry contacts that can be connected to monitoring systems to report failure status, enabling remote operations and maintenance with a centralized management platform.
Easy DIN-Rail Installation
Standard 35mm DIN-rail clip-on mounting with a compact structure and small footprint, ideal for batch deployment in distribution cabinets. Selection Guide
System Topology
Selection Guide
Model Naming Rules
ZLx - x - V / x - x ZLx Product type 1=Type 1 power surge protector; 2=Type 2 power surge protector; S1=Type 1 (remote signal); S2=Type 2 (remote signal); 3=Type 3 protector; S3=Type 3 (remote signal); 4=signal protector; S4=signal protector (remote signal) x Structure V=varistor; F=spark gap; G=graphite gap; BC=composite x Maximum discharge current Imax 20kA; 40kA; 60kA; 80kA; 100kA x Maximum impulse current Iimp 6kA (6.25kA); 12kA (12.5kA); 15kA; 25kA x Maximum continuous operating voltage Uc AC: 255/275/320/385/440/690/760V; DC: 500/600/800/1000/1200/1500/1800/2000V x Protection mode AC: 1P; 2P; 3P; 4P; 1+NPE; 3+NPE; DC: U; Y Model Protection class Maximum continuous operating voltage Uc Nominal discharge current In Maximum discharge current Imax Voltage protection level Up Response time Number of poles Dimensions (L*W*H mm) Remote signal Local failure indication ZL2-V-40/275-2P T2 275V 20kA 40kA 1.5kV ≤50ns 2P 36*83*67 -- √ ZLS2-V-40/385-2P T2 385V 20kA 40kA 1.8kV ≤50ns 2P 36*83*67 √ √ ZL2-V-40/275-4P T2 275V 20kA 40kA 1.5kV ≤50ns 4P 72*83*67 -- √ ZLS2-V-40/385-4P T2 385V 20kA 40kA 1.8kV ≤50ns 4P 72*83*67 √ √ Technical Parameters
| Model | Protection class / Maximum continuous operating voltage Uc / Nominal discharge current In / Maximum discharge current Imax / Voltage protection level Up / Response time / Number of poles / Dimensions (L*W*H mm) / Remote signal / Local failure indication |
| ZL2-V-40/275-2P | T2 / 275V / 20kA / 40kA / 1.5kV / ≤50ns / 2P / 36*83*67 / -- / √ |
| ZLS2-V-40/385-2P | T2 / 385V / 20kA / 40kA / 1.8kV / ≤50ns / 2P / 36*83*67 / √ / √ |
| ZL2-V-40/275-4P | T2 / 275V / 20kA / 40kA / 1.5kV / ≤50ns / 4P / 72*83*67 / -- / √ |
| ZLS2-V-40/385-4P | T2 / 385V / 20kA / 40kA / 1.8kV / ≤50ns / 4P / 72*83*67 / √ / √ |
Technical Parameters
Basic Parameters
Operating voltage AC 220V Installation method Standard 35mm DIN-rail mounting Operating temperature -40℃~70℃ Operating humidity 5%~95% Dimensions 72*83*67mm (4P) / 36*83*67mm (2P) Housing material Thermoplastic flame-retardant material PBT G20 V0 Protection rating IP20
| Operating voltage | AC 220V |
| Installation method | Standard 35mm DIN-rail mounting |
| Operating temperature | -40℃~70℃ |
| Operating humidity | 5%~95% |
| Dimensions | 72*83*67mm (4P) / 36*83*67mm (2P) |
| Housing material | Thermoplastic flame-retardant material PBT G20 V0 |
| Protection rating | IP20 |
Electrical Performance
Protection class T2 Maximum continuous operating voltage Uc 275V/385V AC Nominal discharge current In 20kA Maximum discharge current Imax 40kA Voltage protection level Up 1.5kV/1.8kV Response time ≤50ns Installation Instructions
| Protection class | T2 |
| Maximum continuous operating voltage Uc | 275V/385V AC |
| Nominal discharge current In | 20kA |
| Maximum discharge current Imax | 40kA |
| Voltage protection level Up | 1.5kV/1.8kV |
| Response time | ≤50ns |
Installation Instructions
a
Installation Dimension Drawing
36mm 2P width 72mm 4P width 83mm Height 35mm Standard DIN rail
Key Points
Definition: The Type 2 surge protective device is a Class II SPD designed by FEXLINK for secondary protection of distribution cabinets, capable of withstanding induced lightning surges of the 8/20μs waveform. Core capabilities: discharge capacity covering 20-80kA with fast response, suitable for graded protection at end-of-line distribution points, and supports smart upgrades with FSS monitoring modules. Applicable scenarios: secondary power protection scenarios such as floor distribution cabinets, computer room PDU, and industrial equipment control cabinets. Related products: Type 1 surge protective device, FSS intelligent surge protective device, FS surge protective device monitor.
FAQ
Related Products

FS Lightning-Protection Monitor
SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

FSS Smart Surge Protective Device
Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.

FL Lightning-Current Monitor
Peak lightning current 0.1-200kA measurement, GPS/BeiDou timing, IP67 outdoor protection, precise lightning-event attribution.
Learn MoreT2 Surge Arrester (MOV Type) Application Scenarios
Contact us for detailed solutions, quotes and technical support.