T1-36 mm Split Surge Protective Device
ZL1-V-12/275-4P
Split construction for T1 class direct lightning strike protection: the SPD module separates from the base so modules are replaced without rewiring, in a 36mm width that fits compact cabinets.

Product Overview
Split construction for T1 class direct lightning strike protection: the SPD module separates from the base so modules are replaced without rewiring, in a 36mm width that fits compact cabinets.
Core capabilities
Direct Strike Protection: Iimp up to 25kA (10/350μs). Nanosecond Response: ≤50ns / ≤100ns lightning current discharge. Pluggable Split Design: Module separates from the base, replacement without rewiring.
Data Generated
Product Features
Direct Strike Protection
Iimp up to 25kA (10/350μs)
Nanosecond Response
≤50ns / ≤100ns lightning current discharge
Pluggable Split Design
Module separates from the base, replacement without rewiring
Local Failure Indication
Failure window changes colour, visible during inspection rounds
Remote Signalling
ZLS1 series supports dry contact remote alarm
Compact 36mm
Narrow body fits distribution cabinets with limited space
System Topology
Technical Parameters
Technical Data
Operating voltage AC 220V Protection class T1 Maximum continuous operating voltage Uc 275 / 320 / 385V AC Maximum impulse current Iimp 12.5 / 15 / 25kA (10/350μs) Voltage protection level Up 1.5kV / 2.5kV Response time ≤50ns / ≤100ns
| Operating voltage | AC 220V |
| Protection class | T1 |
| Maximum continuous operating voltage Uc | 275 / 320 / 385V AC |
| Maximum impulse current Iimp | 12.5 / 15 / 25kA (10/350μs) |
| Voltage protection level Up | 1.5kV / 2.5kV |
| Response time | ≤50ns / ≤100ns |
| Mounting | Standard 35mm DIN rail (split base) |
| Operating temperature | -40℃ ~ +70℃ |
| Operating humidity | 5% ~ 95% |
| Housing material | Thermoplastic flame-retardant PBT G20 V0 |
| Protection degree | IP20 |
| Protection modes | 1P / 2P / 3P / 4P / 1+NPE / 3+NPE |
| Replacement | Pluggable module replacement, base keeps wiring |
| Remote signalling | Dry signalling contact on ZLS1 series |
Installation Instructions
Standard 35 mm DIN rail mounting; terminals: supply side L1/L2/L3, N, PE, communication and signal terminals as marked on the device.
Key Points
FAQ
Related Products

FS Lightning-Protection Monitor
SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

FSS Smart Surge Protective Device
Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.