Smart Lightning Protection

DZ47 Surge Protective Backup Protector

SDSCB40

T2 class surge protection with S-suffix signalling models that report failure status remotely; standard 35mm DIN rail clip mounting.

≤50ns40kA0.3s
DZ47 Surge Protective Backup Protector

Product Overview

T2 class surge protection with S-suffix signalling models that report failure status remotely; standard 35mm DIN rail clip mounting.

Core capabilities

T2 Class Protection: Effectively discharges induced lightning surges and internal grid overvoltages. High Surge Capacity: Nominal discharge current 20kA, maximum 40kA. Low Residual Voltage: Voltage protection level down to 1.5kV with response time ≤50ns.

Data Generated

≤50ns40kA0.3s

Product Features

T2 Class Protection

Effectively discharges induced lightning surges and internal grid overvoltages

High Surge Capacity

Nominal discharge current 20kA, maximum 40kA

Low Residual Voltage

Voltage protection level down to 1.5kV with response time ≤50ns

Multiple Configurations

2P/4P and 275V/385V combinations, compatible with AC and DC

Remote Signalling

S-suffix models carry a built-in dry contact for failure status reporting

Easy Rail Mounting

Standard 35mm rail clip design, suited to volume deployment

System Topology

Perception LayerElectrical Parameters · Leakage Detection · Temperature · Arc · Lightning Current · SPD StatusEdge LayerEdge Gateway · Smart Circuit Breaker · Protocol Acquisition · Rule EnginePlatform LayerFEXLINK Cloud · W-Link · Device Access · Data StorageApplication LayerIndustrial AI Analysis · Virtual Power Plant · Energy Monitoring · Carbon Assets · Carbon-Neutral Park

Technical Parameters

Technical Data

Rated operating voltage Ue 230/400V AC Operating frequency 50/60Hz Maximum continuous operating voltage Uc 275V / 385V Nominal discharge current In 10 / 20 / 30 / 40kA Maximum discharge current Imax 20 / 40 / 60 / 80 / 100kA Voltage protection level Up 1.5kV (Uc=275V) / 1.8kV (Uc=385V)

Rated operating voltage Ue230/400V AC
Operating frequency50/60Hz
Maximum continuous operating voltage Uc275V / 385V
Nominal discharge current In10 / 20 / 30 / 40kA
Maximum discharge current Imax20 / 40 / 60 / 80 / 100kA
Voltage protection level Up1.5kV (Uc=275V) / 1.8kV (Uc=385V)
Response time≤50ns
Power-frequency short-circuit operating current3A
Power-frequency disconnection time0.3s
Power-frequency current disconnection cycles1000 cycles
Poles1P / 2P / 3P / 4P
Maximum conductor cross-section6~25mm²
Ambient temperature-40℃ ~ +80℃
Dimensions87.5×81.5×18mm (single pole)
Remote signallingBuilt-in dry contact on S-suffix models
MountingStandard 35mm DIN rail

Installation Instructions

Standard 35 mm DIN rail mounting; terminals: supply side L1/L2/L3, N, PE, communication and signal terminals as marked on the device.

Key Points

FAQ

Two models are offered, SDSCB40 and SDSCB20, with maximum discharge currents of 40kA and 20kA (8/20μs) respectively. They are matched to SPDs rated ≤40kA and ≤20kA.
The housing structure differs: the DZ47 version matches the mounting position and appearance system of DZ47 series distribution boxes. Electrical parameters are given at test class T3, with power-frequency short-circuit breaking capacity of 25kA and 15kA.
Models with the S suffix contain a built-in dry contact that reports failure status to a monitoring system for remote maintenance. A local failure indication window is still provided on the device.
The device clips onto a standard 35mm rail, with a single-pole outline of 87.5×81.5×18mm and maximum conductor cross-section of 6~25mm². Pole options are 1P/2P/3P/4P.
Operating temperature is -40℃ to +80℃ and the device withstands 1000 power-frequency current disconnections. Certification is CE / CMA / CNAS accredited laboratory, and price is Request a quote.

Related Products

RecommendedFS Lightning-Protection Monitor

FS Lightning-Protection Monitor

FS-33211

SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

SPD online monitoringuA-level leakageFour/Five-element / Nine-elementLife trend
View Details →Smart Lightning Protection
FSS Smart Surge Protective Device

FSS Smart Surge Protective Device

FSS Series

Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.

Integrated smart SPDLCD/OLEDBuilt-in communicationStatus monitoring
View Details →Smart Lightning Protection
FL Lightning-Current Monitor

FL Lightning-Current Monitor

FL Series

Peak lightning current 1kA-120kA measurement, GPS/BeiDou timing, IP67 outdoor protection, precise lightning-event attribution.

1kA-120kA peakGPS/BeiDouIP67Event attribution
View Details →Smart Lightning Protection

Learn MoreDZ47 Surge Protective Backup Protector Application Scenarios

Contact us for detailed solutions, quotes and technical support.