DZ47 Surge Protective Backup Protector
SDSCB40
T2 class surge protection with S-suffix signalling models that report failure status remotely; standard 35mm DIN rail clip mounting.

Product Overview
T2 class surge protection with S-suffix signalling models that report failure status remotely; standard 35mm DIN rail clip mounting.
Core capabilities
T2 Class Protection: Effectively discharges induced lightning surges and internal grid overvoltages. High Surge Capacity: Nominal discharge current 20kA, maximum 40kA. Low Residual Voltage: Voltage protection level down to 1.5kV with response time ≤50ns.
Data Generated
Product Features
T2 Class Protection
Effectively discharges induced lightning surges and internal grid overvoltages
High Surge Capacity
Nominal discharge current 20kA, maximum 40kA
Low Residual Voltage
Voltage protection level down to 1.5kV with response time ≤50ns
Multiple Configurations
2P/4P and 275V/385V combinations, compatible with AC and DC
Remote Signalling
S-suffix models carry a built-in dry contact for failure status reporting
Easy Rail Mounting
Standard 35mm rail clip design, suited to volume deployment
System Topology
Technical Parameters
Technical Data
Rated operating voltage Ue 230/400V AC Operating frequency 50/60Hz Maximum continuous operating voltage Uc 275V / 385V Nominal discharge current In 10 / 20 / 30 / 40kA Maximum discharge current Imax 20 / 40 / 60 / 80 / 100kA Voltage protection level Up 1.5kV (Uc=275V) / 1.8kV (Uc=385V)
| Rated operating voltage Ue | 230/400V AC |
| Operating frequency | 50/60Hz |
| Maximum continuous operating voltage Uc | 275V / 385V |
| Nominal discharge current In | 10 / 20 / 30 / 40kA |
| Maximum discharge current Imax | 20 / 40 / 60 / 80 / 100kA |
| Voltage protection level Up | 1.5kV (Uc=275V) / 1.8kV (Uc=385V) |
| Response time | ≤50ns |
| Power-frequency short-circuit operating current | 3A |
| Power-frequency disconnection time | 0.3s |
| Power-frequency current disconnection cycles | 1000 cycles |
| Poles | 1P / 2P / 3P / 4P |
| Maximum conductor cross-section | 6~25mm² |
| Ambient temperature | -40℃ ~ +80℃ |
| Dimensions | 87.5×81.5×18mm (single pole) |
| Remote signalling | Built-in dry contact on S-suffix models |
| Mounting | Standard 35mm DIN rail |
Installation Instructions
Standard 35 mm DIN rail mounting; terminals: supply side L1/L2/L3, N, PE, communication and signal terminals as marked on the device.
Key Points
FAQ
Related Products

FS Lightning-Protection Monitor
SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

FSS Smart Surge Protective Device
Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.

FL Lightning-Current Monitor
Peak lightning current 1kA-120kA measurement, GPS/BeiDou timing, IP67 outdoor protection, precise lightning-event attribution.
Learn MoreDZ47 Surge Protective Backup Protector Application Scenarios
Contact us for detailed solutions, quotes and technical support.