C65 Surge Protective Backup Protector
SCSCB15
Limits induced lightning surges and internal grid overvoltages; 35mm DIN rail mounting, 2P/4P options, covering T1/T2/T3 test classes.

Product Overview
Limits induced lightning surges and internal grid overvoltages; 35mm DIN rail mounting, 2P/4P options, covering T1/T2/T3 test classes.
Core capabilities
Low Residual Voltage: Voltage protection level down to 1.5kV with response time ≤50ns, clamping overvoltages quickly. Multiple Configurations: 2P/4P and 275V/385V combinations, compatible with AC and DC systems. High Surge Capacity: Nominal discharge current 20kA, maximum 40kA, absorbing high-energy impulses.
Data Generated
Product Features
Low Residual Voltage
Voltage protection level down to 1.5kV with response time ≤50ns, clamping overvoltages quickly
Multiple Configurations
2P/4P and 275V/385V combinations, compatible with AC and DC systems
High Surge Capacity
Nominal discharge current 20kA, maximum 40kA, absorbing high-energy impulses
T2 Class Protection
Effectively discharges induced lightning surges and internal grid overvoltages
Fast Response
Completes energy discharge within ≤50ns, protecting downstream precision equipment
Compact Design
2P is 36mm wide and 4P is 72mm wide, saving distribution box space
System Topology
Technical Parameters
Technical Data
Rated operating voltage 230/400V AC Operating frequency 50/60Hz Maximum continuous operating voltage Uc 275V / 385V AC Nominal discharge current In 10 / 20 / 30 / 40kA Maximum discharge current Imax 20 / 40 / 60 / 80 / 100kA Voltage protection level Up 1.5kV (Uc=275V) / 1.8kV (Uc=385V)
| Rated operating voltage | 230/400V AC |
| Operating frequency | 50/60Hz |
| Maximum continuous operating voltage Uc | 275V / 385V AC |
| Nominal discharge current In | 10 / 20 / 30 / 40kA |
| Maximum discharge current Imax | 20 / 40 / 60 / 80 / 100kA |
| Voltage protection level Up | 1.5kV (Uc=275V) / 1.8kV (Uc=385V) |
| Response time | ≤50ns |
| Power-frequency short-circuit operating current | 3A |
| Power-frequency disconnection time | 0.3s |
| Power-frequency current disconnection cycles | 1000 cycles |
| Poles | 1P / 2P / 3P / 4P |
| Maximum conductor cross-section | 6~25mm² |
| Ambient temperature | -40℃ ~ +80℃ |
| Dimensions | 87.5×81.5×18mm (single pole) |
| Remote signalling | Ordered separately |
| Mounting | Standard 35mm DIN rail |
Installation Instructions
Standard 35 mm DIN rail mounting; terminals: supply side L1/L2/L3, N, PE, communication and signal terminals as marked on the device.
Key Points
FAQ
Related Products

FS Lightning-Protection Monitor
SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

FSS Smart Surge Protective Device
Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.

FL Lightning-Current Monitor
Peak lightning current 1kA-120kA measurement, GPS/BeiDou timing, IP67 outdoor protection, precise lightning-event attribution.
Learn MoreC65 Surge Protective Backup Protector Application Scenarios
Contact us for detailed solutions, quotes and technical support.