Smart Lightning Protection

C65 Surge Protective Backup Protector

SCSCB15

Limits induced lightning surges and internal grid overvoltages; 35mm DIN rail mounting, 2P/4P options, covering T1/T2/T3 test classes.

≤50ns100kA0.3s
C65 Surge Protective Backup Protector

Product Overview

Limits induced lightning surges and internal grid overvoltages; 35mm DIN rail mounting, 2P/4P options, covering T1/T2/T3 test classes.

Core capabilities

Low Residual Voltage: Voltage protection level down to 1.5kV with response time ≤50ns, clamping overvoltages quickly. Multiple Configurations: 2P/4P and 275V/385V combinations, compatible with AC and DC systems. High Surge Capacity: Nominal discharge current 20kA, maximum 40kA, absorbing high-energy impulses.

Data Generated

≤50ns100kA0.3s

Product Features

Low Residual Voltage

Voltage protection level down to 1.5kV with response time ≤50ns, clamping overvoltages quickly

Multiple Configurations

2P/4P and 275V/385V combinations, compatible with AC and DC systems

High Surge Capacity

Nominal discharge current 20kA, maximum 40kA, absorbing high-energy impulses

T2 Class Protection

Effectively discharges induced lightning surges and internal grid overvoltages

Fast Response

Completes energy discharge within ≤50ns, protecting downstream precision equipment

Compact Design

2P is 36mm wide and 4P is 72mm wide, saving distribution box space

System Topology

Perception LayerElectrical Parameters · Leakage Detection · Temperature · Arc · Lightning Current · SPD StatusEdge LayerEdge Gateway · Smart Circuit Breaker · Protocol Acquisition · Rule EnginePlatform LayerFEXLINK Cloud · W-Link · Device Access · Data StorageApplication LayerIndustrial AI Analysis · Virtual Power Plant · Energy Monitoring · Carbon Assets · Carbon-Neutral Park

Technical Parameters

Technical Data

Rated operating voltage 230/400V AC Operating frequency 50/60Hz Maximum continuous operating voltage Uc 275V / 385V AC Nominal discharge current In 10 / 20 / 30 / 40kA Maximum discharge current Imax 20 / 40 / 60 / 80 / 100kA Voltage protection level Up 1.5kV (Uc=275V) / 1.8kV (Uc=385V)

Rated operating voltage230/400V AC
Operating frequency50/60Hz
Maximum continuous operating voltage Uc275V / 385V AC
Nominal discharge current In10 / 20 / 30 / 40kA
Maximum discharge current Imax20 / 40 / 60 / 80 / 100kA
Voltage protection level Up1.5kV (Uc=275V) / 1.8kV (Uc=385V)
Response time≤50ns
Power-frequency short-circuit operating current3A
Power-frequency disconnection time0.3s
Power-frequency current disconnection cycles1000 cycles
Poles1P / 2P / 3P / 4P
Maximum conductor cross-section6~25mm²
Ambient temperature-40℃ ~ +80℃
Dimensions87.5×81.5×18mm (single pole)
Remote signallingOrdered separately
MountingStandard 35mm DIN rail

Installation Instructions

Standard 35 mm DIN rail mounting; terminals: supply side L1/L2/L3, N, PE, communication and signal terminals as marked on the device.

Key Points

FAQ

The range covers five models, SCSCB15, SCSCB20, SCSCB40, SCSCB60 and SCSCB80, in T1 and T2/T3 test classes. Maximum discharge current runs from 20kA to 100kA, and SCSCB15 is the T1 variant with 15kA maximum impulse current.
It is connected in series ahead of the SPD and provides power-frequency short-circuit breaking capacity of up to 50kA. Operating current is 3A and disconnection time is 0.3s, preventing fire when a degraded SPD short-circuits.
SCSCB15 belongs to test class T1 with a maximum impulse current of 15kA (10/350μs), so it sits at the direct lightning strike entry. The other models are T2/T3 classes, matched to SPDs of 20kA to 80kA on the 8/20μs waveform.
Mounting is on a standard 35mm DIN rail, with a single-pole outline of 87.5×81.5×18mm and maximum conductor cross-section of 6~25mm². The supply side is wired to L1/L2/L3, N and PE.
Operating temperature ranges from -40℃ to +80℃ and the device withstands 1000 power-frequency current disconnections. Certification is CE / CMA / CNAS accredited laboratory, and price is Request a quote per project.

Related Products

RecommendedFS Lightning-Protection Monitor

FS Lightning-Protection Monitor

FS-33211

SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

SPD online monitoringuA-level leakageFour/Five-element / Nine-elementLife trend
View Details →Smart Lightning Protection
FSS Smart Surge Protective Device

FSS Smart Surge Protective Device

FSS Series

Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.

Integrated smart SPDLCD/OLEDBuilt-in communicationStatus monitoring
View Details →Smart Lightning Protection
FL Lightning-Current Monitor

FL Lightning-Current Monitor

FL Series

Peak lightning current 1kA-120kA measurement, GPS/BeiDou timing, IP67 outdoor protection, precise lightning-event attribution.

1kA-120kA peakGPS/BeiDouIP67Event attribution
View Details →Smart Lightning Protection

Learn MoreC65 Surge Protective Backup Protector Application Scenarios

Contact us for detailed solutions, quotes and technical support.