FL Transient Current Monitor (Outdoor)
FL-11122
High-sensitivity transient current monitoring for the 0.1kA~1kA range, covering the blind spot of low-amplitude lightning currents and switching overvoltages.

Product Overview
High-sensitivity transient current monitoring for the 0.1kA~1kA range, covering the blind spot of low-amplitude lightning currents and switching overvoltages.
Core capabilities
Precise transient capture: Peak value, polarity and time of occurrence recorded for each event.. 100-record circular storage: 100 records held in a circular buffer.. Local alarm indication: The indicator changes from green to red above the threshold..
Data Generated
Product Features
Precise transient capture
Peak value, polarity and time of occurrence recorded for each event.
100-record circular storage
100 records held in a circular buffer.
Local alarm indication
The indicator changes from green to red above the threshold.
Multiple communication options
RS485, Zigbee or Ethernet.
High sensitivity, low range
0.1kA~1kA covers low-amplitude events.
Outdoor-rated enclosure
IP65 housing with -20℃~60℃ operating range.
System Topology
Technical Parameters
Technical Data
Sensor Rogowski coil Range 0.1kA ~ 1kA Recorded data Peak value, polarity, time of occurrence Storage 100 records, circular Alarm threshold Locally settable Communication RS485 / Zigbee / Ethernet
| Sensor | Rogowski coil |
| Range | 0.1kA ~ 1kA |
| Recorded data | Peak value, polarity, time of occurrence |
| Storage | 100 records, circular |
| Alarm threshold | Locally settable |
| Communication | RS485 / Zigbee / Ethernet |
| Power supply | DC12V / AC220V / solar / lithium battery |
| Degree of protection | IP65 |
| Operating temperature | -20℃ ~ 60℃ |
| Mounting | Outdoor wall mount / pole mount |
Installation Instructions
Standard 35 mm DIN rail mounting; terminals: supply side L1/L2/L3, N, PE, communication and signal terminals as marked on the device.
Key Points
FAQ
Related Products

FS Lightning-Protection Monitor
SPD online monitoring, microamp-accuracy leakage-current detection, supporting four/five-element and nine-element monitoring, full visibility of SPD status and life trend.

FSS Smart Surge Protective Device
Integrated smart SPD with built-in monitoring and communication, LCD/OLED display, combined lightning protection and status monitoring.

FL Lightning-Current Monitor
Peak lightning current 1kA-120kA measurement, GPS/BeiDou timing, IP67 outdoor protection, precise lightning-event attribution.
Learn MoreFL Transient Current Monitor (Outdoor) Application Scenarios
Contact us for detailed solutions, quotes and technical support.