Electrical Safety

FA Arc-Fault Monitor

FA / FAP Series

Compliant with UL 1699B, early identification of arc faults, combining with the AI analysis system for hidden-risk identification and confidence scoring.

UL 1699BArc identificationAI warningConfidence scoring
FA Arc-Fault Monitor

Product Overview

The SFA multi-factor electrical intelligent measurement and control unit is a multi-factor integrated intelligent measurement and control terminal developed by FEXLINK for energy management and electrical safety monitoring. It integrates collection, control, communication, and management in one unit, with gateway capabilities, and can be mounted on a 35mm standard DIN rail inside electrical control cabinets, distribution cabinets, or on the outside of monitored equipment. Standard configurations include full electrical parameter measurement of three-phase voltage, three-phase current, active/reactive power, power factor, system frequency, and active/reactive energy, with support for time-of-use metering of forward/reverse active and reactive energy; optional 0-31st harmonic analysis and three-phase unbalance dynamic monitoring functions; it also supports 4 temperature channels, 1 temperature and humidity channel, 1 residual current channel, 2 digital inputs, and 2 relay outputs. With matching dedicated transformers, it covers a current monitoring range of 5A~1000A (expandable up to 6000A), RS485/4G/RJ45 multi-communication access to the cloud platform, and an OLED high-definition screen for convenient local debugging and inspection.

Core Capabilities

Full electrical parameter measurement: three-phase voltage/current/power/power factor/frequency/energy with 0.2S class energy accuracy. Power quality analysis: 0-31st voltage/current harmonic component measurement and three-phase unbalance dynamic analysis. Multi-factor monitoring: 4 temperature channels + 1 temperature and humidity channel + 1 residual current channel + 2 digital inputs + 2 relay outputs. Wide-range adaptation: with dedicated sensors covering a 0-6000A current range, for cable/busbar applications. Product Features

Data Generated

UL 1699BArc identificationAI warningConfidence scoring

Product Features

Complete Monitoring and Collection Functions

Three-phase full electrical parameter measurement, time-of-use metering of forward/reverse active and reactive energy, 4 temperature channels + 1 temperature and humidity channel + 1 residual current channel + 2 digital inputs + 2 relay outputs - one device meets multi-dimensional monitoring needs.

Power Quality Analysis

Supports 0-31st voltage/current harmonic component measurement and three-phase unbalance dynamic analysis, achieving unbalance monitoring and intelligent statistical analysis at each phase angle (optional function).

High-Precision Metering

Active energy accuracy defaults to Class 0.5, with monitoring accuracy up to Class 0.2S, meeting energy management requirements and working with backend software for time-of-use metering and energy consumption analysis.

Multi-Channel Temperature Monitoring

Supports 4 NTC temperature sensor channels for contact temperature monitoring and analysis, plus 1 temperature and humidity channel to track environmental changes in real time.

Residual Current Monitoring

Supports 1 residual current monitoring channel with a 10~3000mA range and Class 1 accuracy, enabling dynamic leakage detection to eliminate electrical hazards.

Linked Control

Supports 2 relay outputs (AC250V/3A, DC30V/3A) for easy threshold-based or custom linked control, enabling automatic response to anomalies.

Multi-Communication Integration

Two RS485 ports + one RJ45 port, with 4G, Zigbee, and LoRa expansion support, standard Modbus RTU protocol with MQTT support, integrating collection, control, communication, and management with gateway capabilities.

OLED Local Display

High-definition OLED screen + physical buttons for easy local data display and product configuration, convenient for debugging and inspection; an optional HMI screen supports building a fully localized monitoring strategy.

Multi-Module Expansion

Supports access to multiple monitoring modules including power quality, three-phase unbalance, smart meters, equipotential, electrical fire, leakage, digital input, lightning protection, lightning current, and grounding resistance. Selection Guide

System Topology

Perception LayerElectrical Parameters · Leakage Detection · Temperature · Arc · Lightning Current · SPD StatusEdge LayerEdge Gateway · Smart Circuit Breaker · Protocol Acquisition · Rule EnginePlatform LayerFEXLINK Cloud · W-Link · Device Access · Data StorageApplication LayerIndustrial AI Analysis · Virtual Power Plant · Energy Monitoring · Carbon Assets · Carbon-Neutral Park

Selection Guide

Model Naming Rules

SFA - 1 0 0 1 1 - GR SFA Product category Multi-factor electrical intelligent measurement and control unit, meter model 1 Meter function 0: none; 1: available 0 Three-phase balance function 0: none; 1: available 0 Harmonic monitoring function 0: none; 1: available 1 Electrical fire function 0: none; 1: available 1 Inputs and outputs 1: 2 relay outputs + 4 digital inputs G Uplink communication method E: Ethernet; G: 4G R Downlink communication method R: RS485 Model Digital inputs Relay outputs Meter monitoring Phase monitoring Harmonic monitoring Downstream RS485 Uplink WAN Uplink 4G SFA-10011-ER 4 2 Supported Not supported Not supported Two channels Supported -- SFA-10011-GR 4 2 Supported Not supported Not supported Two channels -- Supported Current transformer selection (ZCT) Model: ZCT-9(C)-5/0.5 - Inner diameter: 9.5/16/24/36/50mm - Application: C cable / B busbar - Current: 5~1500A - Accuracy: Class 0.2/0.5/1.0 Residual current transformer (ZRCT) Model: ZRCT-45(C)/0.5 - Inner diameter: 30/45/65/80/100/150mm - Application: C cable / B busbar - Accuracy: Class 0.2/0.5/1.0 Temperature sensor (ZTS) Model: ZTS-01 - 01: NTC temperature sensor - 02: digital temperature chip sensor - Monitoring range: -30~125℃ - Accuracy: ±1℃ ZCT

ModelDigital inputs / Relay outputs / Meter monitoring / Phase monitoring / Harmonic monitoring / Downstream RS485 / Uplink WAN / Uplink 4G
SFA-10011-ER4 / 2 / Supported / Not supported / Not supported / Two channels / Supported / --
SFA-10011-GR4 / 2 / Supported / Not supported / Not supported / Two channels / -- / Supported

Current Transformer Selection Chart

With dedicated current transformers covering a 5A~1000A current range, supporting cable/busbar applications with optional Class 0.2/0.5/1.0 accuracy. Rated value 5A 100A 200A 400A 600A 1000A Current ratio 5A/0.33V 100A/0.33V 200A/0.33V 400A/0.33V 600A/0.33V 1000A/0.33V Aperture 16mm 24mm 24mm 36mm 36mm 36mm 5A 100A 200A 400A 600A 1000A ZRCT

Rated value5A / 100A / 200A / 400A / 600A / 1000A
Current ratio5A/0.33V / 100A/0.33V / 200A/0.33V / 400A/0.33V / 600A/0.33V / 1000A/0.33V
Aperture16mm / 24mm / 24mm / 36mm / 36mm / 36mm

Residual Current Transformer Selection Chart

Inner diameter 30/45/65/80/100/150mm optional, supporting cable/busbar applications with Class 0.2/0.5/1.0 accuracy and a 10~3000mA monitoring range. ZTS

Temperature Sensor Selection Chart

NTC temperature sensor (ZTS-01) and digital temperature chip sensor (ZTS-02) are optional, with a -30~125℃ monitoring range and ±1℃ accuracy. Technical Parameters

Technical Parameters

Basic Parameters

Operating voltage AC 180~250V (220V) Power consumption ≤2W Operating temperature -20℃~60℃ Operating humidity <95% Product weight 260g Dimensions 107×88×63mm (L×W×H) Housing material Thermoplastic material UL94V0 Protection rating IP20 Installation method Standard 35mm DIN-rail mounting Display OLED high-definition screen

Operating voltageAC 180~250V (220V)
Power consumption≤2W
Operating temperature-20℃~60℃
Operating humidity<95%
Product weight260g
Dimensions107×88×63mm (L×W×H)
Housing materialThermoplastic material UL94V0
Protection ratingIP20
Installation methodStandard 35mm DIN-rail mounting
DisplayOLED high-definition screen

Monitoring and Communication Parameters

Communication RS485 / 4G / RJ45 Communication protocol Modbus RTU / MQTT Voltage monitoring Rated 220V/380V, accuracy Class 0.5/0.2S Current monitoring 5A/100A/200A/400A/600A/1000A, accuracy Class 0.5 Frequency 45~65Hz, accuracy 0.01Hz Active energy accuracy Class 0.5/0.2S Reactive energy accuracy Class 2 Residual current 10~3000mA, accuracy Class 1 Temperature monitoring -30~125℃, ±1℃ Humidity monitoring 0~100%RH, ±2%RH Digital inputs 4 dry contact inputs with built-in power supply Relay outputs 2 normally open contacts, AC250V/3A, DC30V/3A Installation Instructions

CommunicationRS485 / 4G / RJ45
Communication protocolModbus RTU / MQTT
Voltage monitoringRated 220V/380V, accuracy Class 0.5/0.2S
Current monitoring5A/100A/200A/400A/600A/1000A, accuracy Class 0.5
Frequency45~65Hz, accuracy 0.01Hz
Active energyAccuracy Class 0.5/0.2S
Reactive energyClass 2
Residual current10~3000mA, accuracy Class 1
Temperature monitoring-30~125℃, ±1℃
Humidity monitoring0~100%RH, ±2%RH
Digital inputs4 dry contact inputs with built-in power supply
Relay outputs2 normally open contacts, AC250V/3A, DC30V/3A

Installation Instructions

a

Installation Diagram

35mm DIN-rail mounting dimension drawing b

Interface Description

Interface diagram Terminal definition Category Terminal Definition Voltage input A1/A3/A5/A7 A/B/C phase voltage input, neutral input Power output 5V/12V/G 5V/12V power output, 0V Current input B1~B6 A/B/C phase current input positive/negative terminals Residual current B7/B8 Residual current input negative/positive terminals RS485 communication E5~E8 RS485-1 master/RS485-2 slave A/B terminals DI input C7/C8/E1/E2 Digital inputs 1~4 (connect to GND) Temperature C1~C6 NTC temperature 1~4 inputs, GND Relay outputs D1/D2/D4/D5 Output 1/Output 2 terminals Meter calibration E3/E4 Meter calibration input positive/negative terminals

CategoryTerminal / Definition
Voltage inputA1/A3/A5/A7 / A/B/C phase voltage input, neutral input
Power output5V/12V/G / 5V/12V power output, 0V
Current inputB1~B6 / A/B/C phase current input positive/negative terminals
Residual currentB7/B8 / Residual current input negative/positive terminals
RS485 communicationE5~E8 / RS485-1 master/RS485-2 slave A/B terminals
DI inputC7/C8/E1/E2 / Digital inputs 1~4 (connect to GND)
TemperatureC1~C6 / NTC temperature 1~4 inputs, GND
Relay outputsD1/D2/D4/D5 / Output 1/Output 2 terminals
Meter calibrationE3/E4 / Meter calibration input positive/negative terminals

Key Points

Definition: The SFA multi-factor electrical intelligent measurement and control unit is a core product of the FEXLINK cloud-edge intelligent control series, integrating monitoring capabilities for multiple electrical and status quantities. Core capabilities: supports multi-factor collection of residual current, temperature, voltage, current, power, and energy, with built-in transformer selection guidance and RS485/MQTT upload. Applicable scenarios: smart upgrading of distribution cabinets, comprehensive energy and safety monitoring of commercial complexes, and power measurement and control in industrial plants. Related products: ESA electrical safety monitoring terminal, ZSA embedded multi-function meter, ESX intelligent edge computing gateway.

FAQ

The SFA multi-factor electrical intelligent measurement and control unit is a core product of the FEXLINK cloud-edge intelligent control series, integrating monitoring capabilities for multiple electrical and status quantities.
It is suitable for smart upgrading of distribution cabinets, comprehensive energy and safety monitoring of commercial complexes, and power measurement and control in industrial plants.
Compared with single-function measurement and control units, the SFA integrates multi-factor collection capabilities; one device covers both electrical safety and energy management needs.
Mount it on a DIN rail inside the distribution cabinet, connect the voltage/current transformers and residual current transformer, then connect to the RS485 bus.
Submit your requirements via the contact page on the FEXLINK official website, or call 0755-8653 6148 to book a demo and selection consultation. Engineers will provide matching solutions and quotes based on your application scenario.

Related Products

RecommendedESA Full-Factor Smart Meter

ESA Full-Factor Smart Meter

ESA-1001-R / 1002-R / 1003-R

Synchronous capture of voltage, current, power, power factor and 2nd-31st harmonics, 256 samples/cycle, 0.2-class accuracy.

VoltageCurrentPowerHarmonics
View Details →Electrical Safety
ESB Three-Phase Unbalance Detector

ESB Three-Phase Unbalance Detector

ESB Series

Real-time monitoring of three-phase unbalance and zero-sequence current, warning grid-unbalance risks and reducing line losses and equipment wear.

Three-phase unbalanceZero-sequence currentWarningLine-loss analysis
View Details →Electrical Safety
RecommendedESF Electrical-Fire Detector

ESF Electrical-Fire Detector

ESF Series

Adjustable leakage-current monitoring 30-1000mA and temperature detection 0-150 C, compliant with GB 14287, early warning for electrical-fire hazards.

30-1000mA leakage0-150 C temperatureGB14287Early warning
View Details →Electrical Safety

Related Industry Verticals

Related TopicsIndustry keywords related to this page
Electrical Safety
Arc Monitoring SelectionInsulation Monitoring InterfaceLeakage Current Monitoring SignificanceLeakage Current Monitoring HandbookInsulation Monitoring ProtocolArc Monitoring FeaturesInsulation Monitoring National StandardInsulation Monitoring ComparisonLeakage Current Monitoring CasesLeakage Current Monitoring InterfaceInsulation Monitoring ConceptArc Monitoring InterfaceArc Monitoring DefinitionInsulation Monitoring AdvantagesInsulation Monitoring SelectionLeakage Current Monitoring DownloadArc Monitoring DisadvantagesArc Monitoring HandbookInsulation Monitoring FeaturesInsulation Monitoring StatusInsulation Monitoring FunctionLeakage Current Monitoring ConceptLeakage Current Monitoring StandardArc Monitoring ConceptInsulation Monitoring IntroductionInsulation Monitoring StandardInsulation Monitoring DisadvantagesArc Monitoring CasesInsulation Monitoring CasesLeakage Current Monitoring Protocol

Learn MoreFA Arc-Fault Monitor Application Scenarios

Contact us for detailed solutions, quotes and technical support.