Product Overview The ESE Power Quality Monitor is dedicated to low-voltage three-phase circuits, monitoring voltage, current, power, power factor, phase angle, three-phase unbalance and 2nd-31st harmonics in real time. Voltage/current accuracy Class 0.5, with DO alarm outputs for overvoltage, overcurrent, phase loss and DI linkage. DIN rail mounting; RS485 (Modbus) communication can connect to gateways for cloud upload, forming a power monitoring network. Suitable for full electrical parameter metering, statistics and analysis in distribution cabinets. Class 0.5 accuracy | 260+ electrical parameters | 2nd-31st harmonics | RS485 cloud upload

Data Generated

Power qualityHarmonic analysisVoltage deviationEfficiency analysis

Product Features

Key Features

Full Electrical Parameters

Full A/B/C-phase parameter monitoring: active power, reactive power, apparent power, power factor, forward active energy, voltage-current phase angle, voltage deviation, etc.

Full Electrical Energy Metering

Comprehensive metering of A/B/C-phase voltage, frequency, A/B/C-phase current, A/B/C-phase active/reactive power, total active/reactive power, A/B/C-phase apparent power, etc.

Digital Input

Supports 2 digital inputs (DI) for switch status monitoring and linkage control.

Three-Phase Unbalance Analysis

A/B/C-phase voltage/current phase angle, voltage deviation, frequency deviation, zero-sequence current unbalance, negative-sequence voltage unbalance, zero-sequence current unbalance.

Alarm Query Management

Relay output supports linkage control; standard physical buttons support local query, display and settings; RS485 communication with Modbus protocol.

High-Accuracy Measurement

Class 0.5 accuracy by default; with split-core sensors up to Class 0.2s; current monitoring range 0-6000A.

System Topology

Perception LayerElectrical Parameters · Leakage Detection · Temperature · Arc · Lightning Current · SPD StatusEdge LayerEdge Gateway · Smart Circuit Breaker · Protocol Acquisition · Rule EnginePlatform LayerFEXLINK Cloud · W-Link · Device Access · Data StorageApplication LayerIndustrial AI Analysis · Virtual Power Plant · Energy Monitoring · Carbon Assets · Carbon-Neutral Park

Selection Guide

Model Selection Guide ESE - 1 2 3 4 5 - R Digit 1 · Power supply 1=DC5V 2=AC220V Digit 2 · Display 1=OLED Digit 3 · Wiring mode 1=three-phase four-wire Digit 4 · Current parameter 1=0~5A 2=0~100A 3=0~400A 4=0~600A Digit 5 · Input/output 1=1 relay output 2 digital inputs R · Communication RS485

Selection Table

Selection Table Model Power Supply Display Current Voltage Other Electrical Parameters Digital Input Relay Output RS485 MODBUS ESE-12111-R DC5V OLED 0~5A 220/380V All electrical parameters 2 1 Supported ESE-12121-R DC5V OLED 0~100A 220/380V All electrical parameters 2 1 Supported ESE-12131-R DC5V OLED 0~400A 220/380V All electrical parameters 2 1 Supported ESE-12141-R DC5V OLED 0~600A 220/380V All electrical parameters 2 1 Supported ESE-22111-R AC220V OLED 0~5A 220/380V All electrical parameters 2 1 Supported ESE-22121-R AC220V OLED 0~100A 220/380V All electrical parameters 2 1 Supported ESE-22131-R AC220V OLED 0~400A 220/380V All electrical parameters 2 1 Supported ESE-22141-R AC220V OLED 0~600A 220/380V All electrical parameters 2 1 Supported

Selection Table Model Power Supply Display Current Voltage Other Electrical Parameters Digital Input Relay Output RS485 MODBUS ESE-12111-R DC5V OLED 0~5A 220/380V All electrical parameters 2 1 Supported ESE-12121-R DC5V OLED 0~100A 220/380V All electrical parameters 2 1 Supported ESE-12131-R DC5V OLED 0~400A 220/380V All electrical parameters 2 1 Supported ESE-12141-R DC5V OLED 0~600A 220/380V All electrical parameters 2 1 Supported ESE-22111-R AC220V OLED 0~5A 220/380V All electrical parameters 2 1 Supported ESE-22121-R AC220V OLED 0~100A 220/380V All electrical parameters 2 1 Supported ESE-22131-R AC220V OLED 0~400A 220/380V All electrical parameters 2 1 Supported ESE-22141-R AC220V OLED 0~600A 220/380V All electrical parameters 2 1 Supported

ModelPower Supply / Display / Current / Voltage / Other Electrical Parameters / Digital Input / Relay Output / RS485 MODBUS
ESE-12111-RDC5V / OLED / 0~5A / 220/380V / All electrical parameters / 2 / 1 / Supported
ESE-12121-RDC5V / OLED / 0~100A / 220/380V / All electrical parameters / 2 / 1 / Supported
ESE-12131-RDC5V / OLED / 0~400A / 220/380V / All electrical parameters / 2 / 1 / Supported
ESE-12141-RDC5V / OLED / 0~600A / 220/380V / All electrical parameters / 2 / 1 / Supported
ESE-22111-RAC220V / OLED / 0~5A / 220/380V / All electrical parameters / 2 / 1 / Supported
ESE-22121-RAC220V / OLED / 0~100A / 220/380V / All electrical parameters / 2 / 1 / Supported
ESE-22131-RAC220V / OLED / 0~400A / 220/380V / All electrical parameters / 2 / 1 / Supported
ESE-22141-RAC220V / OLED / 0~600A / 220/380V / All electrical parameters / 2 / 1 / Supported

Technical Parameters

Technical Specifications

Basic Parameters

Parameter Specification Operating voltage DC 4.75~5.25V / AC 180~250V Operating temperature -20℃ ~ 60℃ Weight 150g Enclosure material Thermoplastic material UL94V0 Mounting method Standard 35mm DIN rail Communication RS485 Power consumption ≤2W Operating humidity <95% Dimensions 36×110×69mm Protection rating IP20 Display OLED Communication protocol Modbus protocol

ParameterSpecification
Operating voltageDC 4.75~5.25V / AC 180~250V
Operating temperature-20℃ ~ 60℃
Weight150g
Enclosure materialThermoplastic material UL94V0
Mounting methodStandard 35mm DIN rail
CommunicationRS485
Power consumption≤2W
Operating humidity<95%
Dimensions36×110×69mm
Protection ratingIP20
DisplayOLED
Communication protocolModbus protocol

Monitoring Functions

Parameter Specification Voltage (AC) Rated 220V/380V, overload 1.2x/2x (1s), accuracy Class 0.5/0.2s Current (AC) Rated 5A/100A/400A/600A, overload 1.2x/2x (1s), accuracy Class 0.5/0.2s Frequency 45~65Hz, accuracy 0.01Hz Active energy Accuracy Class 1 Reactive energy Accuracy Class 2 Three-phase unbalance Zero-sequence and negative-sequence unbalance 2nd-31st harmonics Accuracy ±1% Digital input Dry contact input, built-in power supply Digital output Relay output, AC250V/3A DC30V/3A, normally open contact

ParameterSpecification
Voltage (AC)Rated 220V/380V, overload 1.2x/2x (1s), accuracy Class 0.5/0.2s
Current (AC)Rated 5A/100A/400A/600A, overload 1.2x/2x (1s), accuracy Class 0.5/0.2s
Frequency45~65Hz, accuracy 0.01Hz
Active energyAccuracy Class 1
Reactive energyAccuracy Class 2
Three-phase unbalanceZero-sequence and negative-sequence unbalance
2nd-31st harmonicsAccuracy ±1%
Digital inputDry contact input, built-in power supply
Digital outputRelay output, AC250V/3A DC30V/3A, normally open contact

Installation Instructions

Installation Guide

Installation Dimensions

35mm DIN Rail OLED 36mm 110mm 69mm Standard 35mm DIN rail mounting, dimensions: 36×110×69mm (L×W×H)

Sensor Description

5A sensor Current ratio 5A/0.33V Aperture 16mm 100A sensor Current ratio 100A/0.33V Aperture 24mm 400A sensor Current ratio 400A/0.33V Aperture 36mm 600A sensor Current ratio 600A/0.33V Aperture 36mm

Terminal Description

Power terminals L1 Live AC220V supply N Neutral AC220V supply 5V DC5V supply GND 0V DC5V supply Note: 220V AC and 5V DC are mutually exclusive RS485 communication A RS485 A signal B RS485 B signal DI inputs DI1 Connect the other end to GND, directionless DI2 Connect the other end to GND, directionless DO outputs DO1 Relay output, directionless DO1' Relay output, directionless Current IA+ / IA- A-phase current IB+ / IB- B-phase current IC+ / IC- C-phase current Voltage L1 A-phase voltage L2 B-phase voltage L3 C-phase voltage N Neutral

Key Points

Definition: The ESE Power Quality Monitor is a FEXLINK electrical monitoring device dedicated to power quality analysis, monitoring harmonics, voltage deviation, flicker and other indicators. Core capabilities: Supports monitoring of power quality indicators including voltage/current harmonic analysis, three-phase unbalance, voltage flicker and frequency deviation, in compliance with standards such as GB/T 15945. Application scenarios: Suitable for scenarios sensitive to power quality, such as data centers, precision manufacturing and hospitals. Related products: ESA electrical safety monitoring terminal, ESB three-phase unbalance monitor, SFA multi-factor measurement and control unit.

FAQ

The ESE Power Quality Monitor is a FEXLINK electrical monitoring device dedicated to power quality analysis, monitoring harmonics, voltage deviation, flicker and other indicators.
It is suitable for scenarios sensitive to power quality, such as data centers, precision manufacturing and hospitals.
Compared with ordinary meters that only measure voltage and current, the ESE provides professional power quality analysis to help identify power supply quality issues.
Mount it on a DIN rail inside the distribution cabinet, connect voltage/current transformers, and configure monitoring parameters over the RS485 bus.
Submit your requirements via the contact page on the FEXLINK website, or call 0755-8653 6148 to book a demo and selection consultation. Our engineers will provide a matching solution and quotation based on your application scenario.

Related Products

RecommendedESA Full-Factor Smart Meter (Rail-Mount)

ESA Full-Factor Smart Meter (Rail-Mount)

ESA-1001-R / 1002-R / 1003-R

Rail-mount installation, synchronous acquisition of voltage/current/power/harmonics, 256 samples/cycle, the energy-data base for energy supervision.

Rail-mountFull-factor acquisition256 samples/cycleEnergy base
View Details →Digital Energy
ESA Embedded Multi-Function Energy Meter

ESA Embedded Multi-Function Energy Meter

ESA Embedded Series

Class 0.2 accuracy, 2nd-31st harmonic analysis, embedded panel mounting, for cabinet fine-grained metering and efficiency analysis.

Class 0.2 accuracy2nd-31st harmonicsEmbeddedFine-grained metering
View Details →Digital Energy
CW Edge Computing Gateway

CW Edge Computing Gateway

CW Series

100+ protocol acquisition, 4G/Wi-Fi/Ethernet cloud, edge computing and rule engine, the hub for energy-data convergence and pre-processing.

100+ protocols4G/Wi-Fi/EthernetEdge computingData convergence
View Details →Digital Energy

Related Industry Verticals

Related TopicsIndustry keywords related to this page
Digital Energy
Energy Consumption Monitoring StatusEnergy Consumption Management IntroductionEnergy Consumption Acquisition DisadvantagesEnergy Efficiency Analysis TutorialDistribution Monitoring StatusEnergy Efficiency Monitoring StandardEnergy Consumption Analysis FunctionEnergy Efficiency Monitoring ProtocolEnergy Consumption Acquisition HandbookDistribution Monitoring ProspectEnergy Consumption Management StatusEnergy Consumption Monitoring AdvantagesEnergy Consumption Management SelectionEnergy Efficiency Management InterfaceEnergy Consumption Analysis ComparisonEnergy Efficiency Analysis FeaturesEnergy Consumption Monitoring FunctionEnergy Consumption Monitoring DifferenceEnergy Efficiency Analysis CasesEnergy Efficiency Management DownloadEnergy Consumption Management PlatformEnergy Consumption Analysis ProspectEnergy Consumption Management TutorialEnergy Consumption Management HandbookDistribution Monitoring DisadvantagesEnergy Efficiency Analysis DisadvantagesDistribution Monitoring AdvantagesEnergy Efficiency Management FunctionEnergy Consumption Acquisition National StandardEnergy Consumption Acquisition Introduction

Learn MoreESE Power-Quality Monitor Application Scenarios

Contact us for detailed solutions, quotes and technical support.