Why Does an SPD Need Online Monitoring?

SPD degradation, increasing leakage current and ground-resistance changes - hidden hazards that traditional inspection cannot find, and how online monitoring solves them. uA-level leakage detection with lightning-current peak capture.

2026-05 Smart Lightning Protection FEXLINK 1 min
Why Does an SPD Need Online Monitoring?

SPD degradation, increasing leakage current and ground-resistance changes - hidden hazards that traditional inspection cannot find, and how online monitoring solves them. uA-level leakage detection with lightning-current peak capture.

Want a deeper look at FEXLINK solutions?

Contact the FEXLINK solutions team for customised solutions and technical support.

Frequently Asked Questions

Why does an SPD need online monitoring instead of periodic manual inspection?

SPD degradation, rising leakage current and ground-resistance drift are hidden hazards that traditional inspection cannot find; the FS Lightning-Protection Monitor records leakage at microamp accuracy, so an SPD is replaced when its data drifts rather than when a walk-around notices.

What does four/five-element and nine-element SPD monitoring actually add?

The FS Lightning-Protection Monitor pairs microamp-accuracy leakage detection with four/five-element and nine-element monitoring and gives full visibility of SPD status and life trend, so condition is judged from measured elements and service life rather than from a nameplate rating alone.

How many lightning-monitoring points can one FG Smart Lightning Gateway aggregate?

Up to 128 lightning-monitoring points are aggregated into unified cloud management, and the gateway is the data hub of an online lightning-protection platform, so site scale is judged by whether the 128-point blocks fit the monitored roster before extra gateways are planned.

Which ground-resistance range does the FR detector cover in online monitoring?

Three-point or precision three-wire online monitoring covers 0.01-2000 Ohm, so grounding is read continuously as the third leg of protection instead of measured once by hand, and an out-of-range value is judged an active grounding fault rather than a maintenance note.

What fault appears when SPD status is only verified at installation?

An integrated SPD such as the FSS model can degrade while mounted, so protection is silently weaker although the unit is still in place; built-in monitoring and status reporting turn that hidden fault into visible data, making replacement an evidence-based judgment.